AUTO SLEEP FUNCTIONS
ChangingSLEEPTimer(DesolderingGun)
By default, the system’s sleep duration is 0 indicating the sleep
timerisdisabled.Toactivatethesleepfunctionfollowtheprocedures.
1. Turn off the Soldering Iron Function switch (“14” from the
control panel) .Ensure that the Desoldering Gun Function
switchisintheoffposition(“12”fromthecontrolpanel).
2. Press and hold the DOWN button of the Soldering Iron
TemperatureAdjustmentbutton(“4”fromthecontrolpanel).
3. The Desoldering Gun Temperature Display (“14” from the
controlpanel).Willswitchto“000t”indicatingitisnowinthe
desoldering gun sleep timer adjustment mode. Release the
DOWN buttonof theSolderingIronTemperatureAdjustment
button
4. UsetheDesolderingGunTemperatureAdjustmentbuttons(“5”
from the control panel) to increase or decrease the sleep
duration.Timerisadjustablefrom1to60minutes,avalueof0
indicatesthatthesleeptimerfunctionisturnedoff.
5. ConfirmthechangebypressingandholdingtheUP”buttonof
the SolderingIron Temperature Adjustment button (“4” from
thecontrolpanel).
13
OPERATING GUIDELINES
To start the automated reworking function, Follow the guide
below:
1. Ensurethatthehotairgunfunctionswitchisdeactivated.
2. Press the Hot Air Gun AutomateFunction Selector (“17” from the
controlpanel)untilthedisplayshows“run”.
3. Press the upbutton of the Hot Air GunTemperature Adjustment
Buttontoinitiatetheautomatedreworkingfunction.
Uponthestartoftheautomatedreworkingfunctionthehotairgun
wouldslowlyheatupuntilitreachesthesettemperatureofsegmentA.
After the set temperature is reached it would maintain the set
temperature for the duration as set in segment A. The displayed
durationwillstartcountingdownuntilthetimerreaches0afterwhichit
willproceedtothenextsegment,repeatingtheprocessuntilitfinishes
all 5 segments. Upon the end of the fifth segment the cool down
functionwillbeactivatedtoautomaticallycooldownthesystembefore
shuttingoff.
NOTES:
1. HotAirGunTemperatureisadjustablebetween100°and480°C.
2. HotAirGunAirflowRateisadjustablebetween15and100.
3. Thehotairgunisequippedwithatemperaturelimitingfeaturetoonly
allowatemperatureriseof3degreespersecond.Thisisinaccordance
with the industry standard allowable temperature rise time to prevent
damagetosensitivecomponents.